bugGNU FreeIPMI - Bugs: bug #8406, Sensors fails to catch Voltage...

 
 

bug #8406: Sensors fails to catch Voltage ALERT on sensor 12 in default mode

Submitted by:  Joseph Ruscio <jruscio>
Submitted on:  Thu 01 Apr 2004 04:45:32 AM UTC  
 
Category: sensorsSeverity: 3 - Normal
Priority: 5 - NormalItem Group: Improper Behaviour
Status: FixedPrivacy: Public
Assigned to: Balamurugan <balamurugan>Open/Closed: Closed
Operating System: None

Add a New Comment(Rich Markup)
   

You are not logged in

Please log in, so followups can be emailed to you.

 

Fri 02 Apr 2004 12:09:44 AM UTC, comment #1:

fixed type conversion data loss.

Balamurugan <balamurugan>
Project MemberIn charge of this item.
Thu 01 Apr 2004 04:45:32 AM UTC, original submission:

Sensors fails to catch a voltage alert condition in default mode. It properly detects the alert condition in both verbose and very verbose mode. Is the same code being used to check alert conditions for all three verbosity levels?

Repeatable Example:

jruscio@cdcdev:~/work/freeipmi_ft$ sudo sensors -s 12
12: Proc Bd +1.2V (Voltage): 1.22 V (low=1.18/nom=1.20/high=1.21) [OK]

jruscio@cdcdev:~/work/freeipmi_ft$ sudo sensors -v -s 12
Record ID: 12
Sensor type: Proc Bd +1.2V (Voltage)
Sensor number: #29
Event/Reading type code: 01h
Lower non-recoverable threshold: 0.00 Volts
Upper non-recoverable threshold: 0.00 Volts
Lower Critical threshold: 1.08 Volts
Upper Critical threshold: 1.31 Volts
Lower non-critical threshold: 0.00 Volts
Upper non-critical threshold: 0.00 Volts
Sensor min. reading: 0.00 Volts
Sensor max. reading: 3.06 Volts
Normal min.: 1.18 Volts
Nominal reading: 1.20 Volts
Normal max: 1.21 Volts
Sensor reading: 1.22 Volts
Sensor status: ALERT

jruscio@cdcdev:~/work/freeipmi_ft$ sudo sensors -vv -s 12
Record ID: 12
Sensor type: Proc Bd +1.2V (Voltage)
Sensor number: #29
Event/Reading type code: 01h
Lower non-recoverable threshold: 0.00 Volts
Upper non-recoverable threshold: 0.00 Volts
Lower Critical threshold: 1.08 Volts
Upper Critical threshold: 1.31 Volts
Lower non-critical threshold: 0.00 Volts
Upper non-critical threshold: 0.00 Volts
Sensor min. reading: 0.00 Volts
Sensor max. reading: 3.06 Volts
Normal min.: 1.18 Volts
Nominal reading: 1.20 Volts
Normal max: 1.21 Volts
Sensor reading: 1.22 Volts
Sensor status: ALERT

Joseph Ruscio <jruscio>

 

(Note: upload size limit is set to 16384 kB, after insertion of the required escape characters.)

Attach File(s):
   
   
Comment:
   

No files currently attached

 

Depends on the following items: None found

Items that depend on this one: None found

 

CC list is empty

 

Do you think this task is very important?
If so, you can click here to add your encouragement to it.
This task has 0 encouragements so far.

Only logged-in users can vote.

 

Please enter the title of George Orwell's famous dystopian book (it's a date):

 

 

Follow 3 latest changes.

Date Changed By Updated Field Previous Value => Replaced By
Fri 02 Apr 2004 12:09:44 AM UTCbalamuruganStatusNone=>Fixed
  Assigned toNone=>balamurugan
  Open/ClosedOpen=>Closed

Back to the top


Powered by Savane 3.1-cleanup1